Model AB25 HYDRO 3000/1800 Watts
Pressure Water Model
AB25 3000/2400 Watts
AB50 5000/4000 Watts
AB60 6000/5000 Watts
Totally brushless with capacitor, copper windings, bi-directional rotation Voltage Plus™ exclusive Smooth Wave™ <6% distortion, CSA listed. |
 |
STANDARD FEATURES
| MODEL |
AB25 HYDRO |
AB25 |
AB50 |
AB60 |
| 120V DUPLEX 15A, 5-15R |
1 |
-- |
-- |
-- |
| 120V DUPLEX 20A, 5-20R |
-- |
1 |
1 |
1 |
| 240V 20A, L14-20R |
-- |
-- |
1 |
1 |
| CIRCUIT BREAKERS |
YES |
YES |
YES |
YES |
| VOLTMETER |
NO |
YES |
YES |
YES |
| SHAFT DIAMETER |
.875"(22) |
.875"(22) |
.875"(22) |
.875"(22) |
| KEYWAY |
.1875(4.7) |
.1875(4.7) |
.1875(4.7) |
.1875(4.7) |
| SHAFT ROTATION FROM PTO VIEW |
BI-DIRECTIONAL |
BI-DIRECTIONAL |
BI-DIRECTIONAL |
BI-DIRECTIONAL |
| SHAFT SPEED RPM |
3600 |
3600 |
3600 |
3600 |
| REQUIRED PULLEY (NOT SUPPLIED) |
SINGLE |
SINGLE |
SINGLE |
SINGLE |
| TIME DELAY WITH LOW VOLTAGE CUT OUT (FOR PRESSURE WASHERS) |
YES |
-- |
-- |
-- |
IMPORTANT - FOR INSTALLATION CONSULT OWNER'S MANUAL.
ALL MODELS DESIGNED FOR HORIZONTAL OPERATION ONLY.
| |
WATTS |
|
| MODEL |
MAXIMUM |
RATED |
VOLTAGE |
AMPS RATED |
HERTZ |
PHASE |
WIRE |
MINIMUM REQUIRED ENGINE H.P. |
REQUIRED TORQUE FT-LBS |
REQUIRED GENERATOR SHAFT RPM |
| AB25 HYDRO |
3000 |
1800 |
120 |
15 |
60 |
1 |
4 |
4 |
7.5 |
3600 |
| AB25 |
3000 |
2400 |
120 |
20 |
60 |
1 |
4 |
5 |
7.5 |
3600 |
| AB50 |
5000 |
4000 |
120/240 |
33.3/16.7 |
60 |
1 |
4 |
8 |
12.5 |
3600 |
| AB60 |
6000 |
5000 |
120/240 |
41.6/20.8 |
60 |
1 |
4 |
11 |
16.5 |
3600 |
| MODEL |
NET |
PACKAGED |
|
|
|
| |
L |
W |
H |
L |
W |
H |
NET WEIGHT |
PACKAGED WEIGHT |
CUBIC FT. |
| AB25 HYDRO |
14.0(35) |
7.125(18) |
7.5(19) |
18.75(47) |
9.6(24) |
9(23) |
33(15) |
44(20) |
1.0 |
| AB25 |
14.0(35) |
7.125(18) |
7.5(19) |
18.75(47) |
9.6(24) |
9(23) |
33(15) |
44(20) |
1.0 |
| AB50 |
14.5(36) |
7.125(18) |
7.5(19) |
18.75(47) |
9.6(24) |
9(23) |
42(19) |
53(24) |
1.0 |
| AB60 |
15(38) |
7.125(18) |
7.5(19) |
18.75(47) |
9.6(24) |
9(23) |
49(22) |
56(25) |
1.0 |

CHANGES: All specifications and dimensions are subject to change without notice and there is no obligation to make changes in units previously sold. All units are manufactured to the highest engineering standards consistent with the industry.
GENERATOR SELECTIONS: When selecting generator be sure that the unit takes care of present total requirments and your
anticipated needs. Motor loads require 3 to 4 times wattage (or amperage) ratings on nameplate.
RATINGS: Apply to altitudes up to 1000 feet, standard cooling, normal ambients and gasoline fuel. Reduce ratings 3-1/2% for each 1000 feet above sea level and 1% for each 10∞ farenheight rise above 60∞ farenheight. Connection of a generator to a home or building requires a transfer switch. Consult a qualified technician.
© 2006 SML Industries, Inc. Disclaimer Information
|